Acoustic panel absorption estimator
Explore how much additional absorption a Sabine room model predicts from a measured reverberation time and a target time. It estimates room treatment, not sound isolation between rooms.
How the calculation works
In SI units, Sabine’s relation is T = 0.161 × V ÷ A. Use measured current time to infer current absorption, and target time to calculate target absorption. Additional absorption is the positive difference. Divide by panel area multiplied by the difference between panel and replaced-surface absorption fractions, then round up.
Worked examples
Example 1
A 50 m³ room changing from 1.2 s to 0.6 s needs about 6.71 m² of additional absorption in this model: 13 panels providing 0.54 m² each.
Example 2
If the measured time is already 0.5 s and the target is 0.6 s, this model calls for no additional absorption.
What this estimate does not cover
Use values from the same frequency band and a manufacturer’s appropriate absorption data. A single NRC number is not a complete frequency response. Sabine assumes an approximately diffuse field and is only an estimate for small or unevenly treated rooms. Mounting, placement, furniture and low-frequency behavior need separate consideration. Example times are illustrative, not measurements of your room.
References
References provide measurement or subject background. The formulas, examples and limitations on this site are our implementation; linked organizations do not endorse this tool.
Method reviewed 2026-11-13. Example inputs are illustrative.